Industries / Data centers

Control optimization for data centers.

Your cooling plant and your on-site generation are held to setpoint by control loops. Optimize those loops and the same equipment delivers more capacity on less energy — nothing replaced, nothing new in the critical path.

Loop response · step change in load
 
Settling First pass, on target
Overshoot None
Valve travel Minimal
Equipment changed None
1985Advanced process control since
500+Projects delivered
60+U.S. power plants
12Industries served
01 / The opportunity

There is money in your plant right now.

You do not need new equipment to find it. You need the loops you already own to hold their targets.

~1/3
   

of loops underperform

The industry norm. Most have never been flagged — the room stayed cool and the unit stayed online.

Widely cited loop-performance studies
1.54
 6 yrs

industry PUE, flat for six years

The remaining points are not in new equipment. They are in how the plant is controlled.

Uptime Institute, 2025
0
 

controllers replaced

Every engagement begins read-only on your existing DCS, BMS or PLC. You see the number before anything changes.

How we start, every time
02 / Where we optimize

Two systems decide what your site costs to run.

Pick the one closest to your critical path. Each has its own scope and its own two-week entry engagement.

A — Cooling control →

Cooling loop optimization

Cooling is the largest controllable load on site. Optimizing the loops beneath it recovers energy and returns capacity you can fill with racks — no capital project.

  1. 01Chiller staging, CHW supply temperature, condenser water
  2. 02Differential-pressure reset — usually the largest single win
  3. 03CDU and liquid-cooling loops at high rack density
  4. 04Economizer changeover and free-cooling hours
B — Power generation control →

On-site generation optimization

Turbines are three years out. Optimizing control on the units you have adds ramp rate, heat rate and availability in weeks — capacity you cannot buy on your timeline.

  1. 01Load acceptance and ramp rate under stepping IT load
  2. 02Emissions control that holds a permit without a derate
  3. 03Drum level and startup sequencing — the common trip paths
  4. 04Islanded operation, load sharing and black start
03 / What you get

Outcomes you can put in front of finance.

Measured in units your CFO and your operations lead both recognize.

kW · $/MW-yrCooling

Energy recovered

From loops that were hunting, saturated, or quietly left in manual.

MW/minPower

Ramp rate gained

So on-site generation can follow a load that steps rather than glides.

PUE pointsCooling

Efficiency, held

What the control layer was giving away — kept there after the tuning visit ends.

Heat ratePower

Less fuel per megawatt

Improved without touching the generating assets.

kW · racksCooling

Cooling capacity reclaimed

Headroom you can fill without a capital project.

Avoided tripsPower

Uptime protected

Latent control faults found before a real load profile finds them.

04 / How it works

Two weeks to a number. Nothing changes until you say so.

Fixed scope, fixed fee. The deliverable is yours whether or not you go further.

01read-only

Assess

We work from your historian and trend data — no downtime, no controller changes. You get a ranked loop inventory, quantified instability and the recoverable energy attached to each.

From $7,500 per site
02your approval

Optimize

Tuning validated across the full operating range, plus model-based control where the physics puts a loop beyond PID. Implemented with your team, on your change-control process.

Scoped from the assessment
03ongoing

Hold

Continuous loop-performance monitoring across the site or fleet. Tuning decays as equipment ages; monitoring is what keeps the savings after the engineers go home.

Site or fleet
05 / Proof

Forty years of the same control problems.

From power stations, treatment plants and process lines — where an unstable loop trips a unit. Client names withheld; full case studies on request.

30.3
MW/min · from 22.8 · $670K/yr

Model predictive control on the duct burners and surrounding loops — with no capital upgrade — qualified the station for dispatch markets its ramp rate had locked it out of.

575 MW combined-cycle
California
<1 wk
on site · $200–300K per trip avoided

Years of random startup trips. Loop analysis isolated a misconfigured controller that armed only in a narrow band — and drove the drum straight into trip territory.

400+ MW unit
Major U.S. energy provider
~38
hp/MGD · from ~58

A two-minute deadtime meant PID never settled, so every downstream pump and blower short-cycled. Model-based control settled the flow — and the whole cascade settled with it.

4.2 MGD treatment plant
U.S. Army installation
06 / Why ControlSoft

Four decades focused on one discipline: process control.

Advanced process control since 1985 — the same discipline, now pointed at the two systems that set what your site costs to run.

  1. Neutral

    We are not selling you equipment

    We sit on top of whatever you run — Schneider, Johnson Controls, Siemens, Vertiv, Trane, a legacy PLC. A mixed fleet gets one consistent measure of loop performance, which no single manufacturer can offer.

  2. Non-intrusive

    Nothing new enters the critical path

    No competing controller, no rip-and-replace, no new hardware. Every recommendation returns to your team as a specific parameter change to review.

  3. Complementary

    Your optimization platform works better on top of us

    Optimization software sets the targets; the control layer beneath has to hold them. We make that layer stable and observable, so pilot savings reproduce across the fleet.

  4. Transferable

    Your engineers keep the capability

    The deliverable is documentation and skill, not dependency. ControlSoft has run formal process-control training for four decades — the intent is that your team can read the plant after we leave.

07 / Request a consultation

Show us your most difficult hall.

A two-week assessment tells you what your control layer is costing you, which loops to fix first, and what the fix is worth. If the numbers are not there, we will say so — and you keep the inventory either way.

What is closest to your critical path?
Control Optimization Assessment
Duration
Two weeks
Commercials
Fixed scope, fixed fee, priced per site — tiers below
Access
Historian and trend exports. Read-only.
Disruption
None. No downtime, no controller changes.
Deliverable
Ranked loop inventory, quantified instability, recoverable energy, costed remediation plan
Suggested price per site
Trend reviewRemote, using exported BMS trend data
$7,500
Core offerRemote, live data, 2 weeks, read-only
$15,000
On-site, coolingOn site + live data, cooling plant
$20,000–25,000+ travel and lodging
On-site, generationOn site + live data, turbines, engines, fuel cells
$25,000–30,000+ travel and lodging